
K-STAR 2 Channel TENS Machine K-280 | Electronic Pain Relief & Acupuncture Stimulator | Dual Channel Physiotherapy Electrotherapy Device | Nerve & Muscle Stimulation Machine
The K-STAR 2 Channel TENS Machine (K-280) is an electronic physiotherapy electrotherapy device designed for controlled electrical stimulation through compatible electrode accessories. It is suitable for professional physiotherapy clinics, rehabilitation centers, hospitals and healthcare facilities. This dual-channel electrotherapy machine is designed to deliver electrical stimulation through two separate output channels. It features individual intensity controls for both channels, allowing trained practitioners to adjust the stimulation output according to the patient's requirements and professional treatment protocol. The machine also features a frequency adjustment control and pulse indicator LEDs, providing convenient access to its available operating controls. Its user-friendly control panel makes it suitable for professional electrotherapy applications involving nerve and muscle stimulation.
The K-STAR 2 Channel TENS Machine can be incorporated into practitioner-guided physiotherapy programs for selected pain management and muscle stimulation applications. It can also be used for compatible acupuncture-related electrical stimulation applications when supported by the device configuration and appropriate accessories. Designed for professional treatment environments, this machine offers a practical electrotherapy solution for physiotherapists and healthcare practitioners looking for a dual-channel electrical stimulation device.
⭐Key Features :
1. 2 Channel Operation: Features two separate output channels for electrical stimulation applications.
2. Individual Intensity Controls: Separate intensity adjustment knobs for Channel 1 and Channel 2.
3. Frequency Adjustment: Includes a frequency control dial for adjusting the available frequency setting.
4. Pulse Indicator LEDs: Indicator lights provide a visual indication of channel operation.
5. Electronic Pain Relief Device: Designed for practitioner-guided TENS and electrotherapy applications.
6. Nerve Stimulation: Supports controlled electrical stimulation through compatible electrodes.
7. Muscle Stimulation: Can be incorporated into selected muscle stimulation programs.
8. Acupuncture Stimulation Applications: Suitable for compatible acupuncture-related stimulation procedures when supported by the model and accessories.
9. Simple Control Panel: Convenient knobs and clearly marked operating controls.
10. Professional Physiotherapy Equipment: Suitable for clinics, hospitals and rehabilitation facilities.
⭐Benefits of this Product :
1. Supports Pain Management Programs: Can be incorporated into professional TENS therapy routines for selected pain conditions.
2. Dual Channel Convenience: Two output channels provide flexibility for practitioner-guided treatment applications.
3. Individual Intensity Adjustment: Allows separate adjustment of stimulation intensity for each channel.
4. Muscle Stimulation Support: Provides an electrical stimulation option for selected physiotherapy programs.
5. Controlled Stimulation: Frequency and intensity controls support adjustment according to professional protocols.
6. Professional Rehabilitation Support: Can complement other physiotherapy and rehabilitation methods.
7. Versatile Clinical Applications: Suitable for selected electrotherapy and compatible acupuncture stimulation procedures.
8. Easy Operation: Straightforward control layout supports convenient operation by trained practitioners.
⭐How to Use K-STAR 2 Channel TENS Machine K-280 – Electronic Pain Relief & Acupuncture Stimulator :
Step-by-Step Usage Instructions-
Step 1: Inspect the Machine
#Check the main unit, power cable, electrode leads, connectors and accessories for visible damage.
#Ensure that the accessories are compatible with the K-280 model.
#Place the machine on a stable, dry and level surface.
#Turn both channel intensity controls to zero or OFF.
#Keep the machine switched off before connecting accessories.
Step 2: Prepare the Patient
#Explain the treatment procedure and obtain the patient's consent.
#Review the patient's medical history and check for contraindications.
#Position the patient comfortably.
#Examine the selected treatment area for wounds, irritation, infection or reduced sensation.
#Ensure that the treatment area is accessible for correct electrode placement.
Step 3: Prepare the Skin
#Clean the selected treatment area according to professional hygiene procedures.
#Allow the skin to dry before applying the electrodes.
#Check that the electrode pads are clean and in good condition.
#Use suitable conductive gel if required by the electrode manufacturer's instructions.
Step 4: Connect the Electrodes
#Keep the machine switched off and both intensity controls at zero.
#Connect the compatible electrode leads to the designated output terminals.
#Attach the electrode pads to the selected treatment area according to the physiotherapist's treatment plan.
#Ensure proper contact between the electrodes and skin.
#Check that the cables are securely connected and not tangled.
Step 5: Switch On the Machine
#Connect the power cable according to the manufacturer's instructions.
#Switch on the machine.
#Check the power indicator and control panel.
#Confirm that the frequency control and both channel intensity controls are in their starting positions.
#Ensure the machine is functioning normally before treatment.
Step 6: Select the Frequency Setting
#Use the frequency adjustment dial to select the setting prescribed by the qualified practitioner.
#Refer to the machine's instruction manual for the available frequency range and adjustment method.
#Do not select settings based on guesswork or copy settings from another TENS machine.
Step 7: Adjust Channel Intensity
#Begin with both channel intensity controls at zero or OFF.
#Activate the required channel according to the machine's instructions.
#Gradually increase the intensity using the corresponding control.
#Adjust the second channel separately if it is required for the treatment.
#Keep stimulation within a comfortable and professionally prescribed range.
#Never increase the intensity suddenly or use maximum intensity without clinical justification.
Step 8: Start the Treatment
#Confirm that the electrodes are properly positioned.
#Check that the patient is comfortable before beginning stimulation.
#Monitor the pulse indicator LEDs during operation.
#Observe the patient's response throughout the session.
#Check for unusual discomfort, burning, excessive muscle contraction or irritation.
#Stop treatment immediately if an adverse reaction occurs.
Step 9: Complete the Treatment
#Gradually reduce both channel intensity controls to zero or OFF.
#Switch off the machine before disconnecting the electrodes.
#Carefully remove the electrode pads from the patient's skin.
#Inspect the treated area for redness or irritation.
#Allow the patient to rest if required.
Step 10: Clean and Store the Machine
#Disconnect the power supply and electrode leads.
#Clean reusable electrodes and accessories according to their manufacturer's instructions.
#Wipe the machine's exterior with a suitable dry or slightly damp cloth.
#Do not immerse the main unit in water.
#Inspect cables and connectors before storage.
#Store the machine and accessories in a clean, dry place.
⭐Important Safety Precautions :
1. Use the machine under the supervision of a qualified physiotherapist or healthcare professional.
2. Do not use on patients with pacemakers or implanted electronic devices unless their treating clinician and the manufacturer specifically confirm it is safe.
3. Pregnancy, epilepsy, heart rhythm disorders and reduced skin sensation require professional medical assessment.
4. Never place electrodes across the chest, on the front or sides of the neck, or over the head.
5. Do not apply electrodes over broken, infected or irritated skin.
6. Never connect or disconnect electrodes while stimulation is active.
7. Always keep intensity controls at zero before connecting electrodes or switching on the machine.
8. Do not use while bathing, sleeping, driving or operating machinery.
9. Monitor the patient throughout the treatment session.
10. Stop immediately if the patient experiences burning, sharp pain, dizziness or unusual discomfort.
⭐Important Note About Acupuncture Stimulation :
1. Acupuncture needle insertion must be performed by a qualified and trained practitioner.
2. Use only compatible, sterile, single-use acupuncture needles and approved connecting leads.
3. Follow the manufacturer's specific instructions for needle connections and stimulation.
4. Do not connect ordinary surface electrode accessories to acupuncture needles unless specifically approved for that purpose.
5. Never connect or disconnect needle clips while electrical stimulation is active.
Available At :
K-STAR INDIA (Khandoliya Industries)
➡️Acupressure & Acupuncture | Physiotherapy | Panchakarma & Magnet | Cupping & Hijama | Product & Equipment
📍Address: Shop No. 3, Near Gurudwara Road, Opposite Union Bank, Block 6, WEA, Karol Bagh, New Delhi – 110005.
📞Contact: 9560379805, 9413023521
9625359462, 08048033068
🌐 Website: www.kstarindia.com
🌐 www.acupressuredelhi.com
📍 Google Map: https://share.google/RxxycSz348HpcxxVm
**Choose Khandoliya Industries — A Name You Can Trust in Natural Wellness.**
The K-STAR 2 Channel TENS Machine (K-280) is an electronic physiotherapy electrotherapy device designed for controlled electrical stimulation through compatible electrode accessories. It is suitable for professional physiotherapy clinics, rehabilitation centers, hospitals and healthcare facilities. This dual-channel electrotherapy machine is designed to deliver electrical stimulation through two separate output channels. It features individual intensity controls for both channels, allowing trained practitioners to adjust the stimulation output according to the patient's requirements and professional treatment protocol. The machine also features a frequency adjustment control and pulse indicator LEDs, providing convenient access to its available operating controls. Its user-friendly control panel makes it suitable for professional electrotherapy applications involving nerve and muscle stimulation.
The K-STAR 2 Channel TENS Machine can be incorporated into practitioner-guided physiotherapy programs for selected pain management and muscle stimulation applications. It can also be used for compatible acupuncture-related electrical stimulation applications when supported by the device configuration and appropriate accessories. Designed for professional treatment environments, this machine offers a practical electrotherapy solution for physiotherapists and healthcare practitioners looking for a dual-channel electrical stimulation device.
⭐Key Features :
1. 2 Channel Operation: Features two separate output channels for electrical stimulation applications.
2. Individual Intensity Controls: Separate intensity adjustment knobs for Channel 1 and Channel 2.
3. Frequency Adjustment: Includes a frequency control dial for adjusting the available frequency setting.
4. Pulse Indicator LEDs: Indicator lights provide a visual indication of channel operation.
5. Electronic Pain Relief Device: Designed for practitioner-guided TENS and electrotherapy applications.
6. Nerve Stimulation: Supports controlled electrical stimulation through compatible electrodes.
7. Muscle Stimulation: Can be incorporated into selected muscle stimulation programs.
8. Acupuncture Stimulation Applications: Suitable for compatible acupuncture-related stimulation procedures when supported by the model and accessories.
9. Simple Control Panel: Convenient knobs and clearly marked operating controls.
10. Professional Physiotherapy Equipment: Suitable for clinics, hospitals and rehabilitation facilities.
⭐Benefits of this Product :
1. Supports Pain Management Programs: Can be incorporated into professional TENS therapy routines for selected pain conditions.
2. Dual Channel Convenience: Two output channels provide flexibility for practitioner-guided treatment applications.
3. Individual Intensity Adjustment: Allows separate adjustment of stimulation intensity for each channel.
4. Muscle Stimulation Support: Provides an electrical stimulation option for selected physiotherapy programs.
5. Controlled Stimulation: Frequency and intensity controls support adjustment according to professional protocols.
6. Professional Rehabilitation Support: Can complement other physiotherapy and rehabilitation methods.
7. Versatile Clinical Applications: Suitable for selected electrotherapy and compatible acupuncture stimulation procedures.
8. Easy Operation: Straightforward control layout supports convenient operation by trained practitioners.
⭐How to Use K-STAR 2 Channel TENS Machine K-280 – Electronic Pain Relief & Acupuncture Stimulator :
Step-by-Step Usage Instructions-
Step 1: Inspect the Machine
#Check the main unit, power cable, electrode leads, connectors and accessories for visible damage.
#Ensure that the accessories are compatible with the K-280 model.
#Place the machine on a stable, dry and level surface.
#Turn both channel intensity controls to zero or OFF.
#Keep the machine switched off before connecting accessories.
Step 2: Prepare the Patient
#Explain the treatment procedure and obtain the patient's consent.
#Review the patient's medical history and check for contraindications.
#Position the patient comfortably.
#Examine the selected treatment area for wounds, irritation, infection or reduced sensation.
#Ensure that the treatment area is accessible for correct electrode placement.
Step 3: Prepare the Skin
#Clean the selected treatment area according to professional hygiene procedures.
#Allow the skin to dry before applying the electrodes.
#Check that the electrode pads are clean and in good condition.
#Use suitable conductive gel if required by the electrode manufacturer's instructions.
Step 4: Connect the Electrodes
#Keep the machine switched off and both intensity controls at zero.
#Connect the compatible electrode leads to the designated output terminals.
#Attach the electrode pads to the selected treatment area according to the physiotherapist's treatment plan.
#Ensure proper contact between the electrodes and skin.
#Check that the cables are securely connected and not tangled.
Step 5: Switch On the Machine
#Connect the power cable according to the manufacturer's instructions.
#Switch on the machine.
#Check the power indicator and control panel.
#Confirm that the frequency control and both channel intensity controls are in their starting positions.
#Ensure the machine is functioning normally before treatment.
Step 6: Select the Frequency Setting
#Use the frequency adjustment dial to select the setting prescribed by the qualified practitioner.
#Refer to the machine's instruction manual for the available frequency range and adjustment method.
#Do not select settings based on guesswork or copy settings from another TENS machine.
Step 7: Adjust Channel Intensity
#Begin with both channel intensity controls at zero or OFF.
#Activate the required channel according to the machine's instructions.
#Gradually increase the intensity using the corresponding control.
#Adjust the second channel separately if it is required for the treatment.
#Keep stimulation within a comfortable and professionally prescribed range.
#Never increase the intensity suddenly or use maximum intensity without clinical justification.
Step 8: Start the Treatment
#Confirm that the electrodes are properly positioned.
#Check that the patient is comfortable before beginning stimulation.
#Monitor the pulse indicator LEDs during operation.
#Observe the patient's response throughout the session.
#Check for unusual discomfort, burning, excessive muscle contraction or irritation.
#Stop treatment immediately if an adverse reaction occurs.
Step 9: Complete the Treatment
#Gradually reduce both channel intensity controls to zero or OFF.
#Switch off the machine before disconnecting the electrodes.
#Carefully remove the electrode pads from the patient's skin.
#Inspect the treated area for redness or irritation.
#Allow the patient to rest if required.
Step 10: Clean and Store the Machine
#Disconnect the power supply and electrode leads.
#Clean reusable electrodes and accessories according to their manufacturer's instructions.
#Wipe the machine's exterior with a suitable dry or slightly damp cloth.
#Do not immerse the main unit in water.
#Inspect cables and connectors before storage.
#Store the machine and accessories in a clean, dry place.
⭐Important Safety Precautions :
1. Use the machine under the supervision of a qualified physiotherapist or healthcare professional.
2. Do not use on patients with pacemakers or implanted electronic devices unless their treating clinician and the manufacturer specifically confirm it is safe.
3. Pregnancy, epilepsy, heart rhythm disorders and reduced skin sensation require professional medical assessment.
4. Never place electrodes across the chest, on the front or sides of the neck, or over the head.
5. Do not apply electrodes over broken, infected or irritated skin.
6. Never connect or disconnect electrodes while stimulation is active.
7. Always keep intensity controls at zero before connecting electrodes or switching on the machine.
8. Do not use while bathing, sleeping, driving or operating machinery.
9. Monitor the patient throughout the treatment session.
10. Stop immediately if the patient experiences burning, sharp pain, dizziness or unusual discomfort.
⭐Important Note About Acupuncture Stimulation :
1. Acupuncture needle insertion must be performed by a qualified and trained practitioner.
2. Use only compatible, sterile, single-use acupuncture needles and approved connecting leads.
3. Follow the manufacturer's specific instructions for needle connections and stimulation.
4. Do not connect ordinary surface electrode accessories to acupuncture needles unless specifically approved for that purpose.
5. Never connect or disconnect needle clips while electrical stimulation is active.
Available At :
K-STAR INDIA (Khandoliya Industries)
➡️Acupressure & Acupuncture | Physiotherapy | Panchakarma & Magnet | Cupping & Hijama | Product & Equipment
📍Address: Shop No. 3, Near Gurudwara Road, Opposite Union Bank, Block 6, WEA, Karol Bagh, New Delhi – 110005.
📞Contact: 9560379805, 9413023521
9625359462, 08048033068
🌐 Website: www.kstarindia.com
🌐 www.acupressuredelhi.com
📍 Google Map: https://share.google/RxxycSz348HpcxxVm
**Choose Khandoliya Industries — A Name You Can Trust in Natural Wellness.**
Keywords






